Wood Burning Fireplace Inserts: How They Work and Fit
Quick answer
A wood burning fireplace insert is a wood stove built to slide into an existing fireplace. Its closed firebox burns wood with metered air, burns off most of the smoke and sends heat into the room instead of up the chimney, where most of an open fire’s heat goes. To work safely it has to fit your firebox and connect to the chimney exactly as its manual requires (often with a full-height stainless steel liner), and any new insert sold in the U.S. must meet EPA’s 2020 smoke limits.
How a wood insert works
You load wood through a door that stays closed and latched while it burns, and an air control sets the burn rate. The fire burns twice: once on the wood, then again as a second burn of the smoke. Non-catalytic models do that with an insulated firebox, a large baffle and preheated air fed in above the fire; catalytic models pass the smoke through a coated ceramic honeycomb that ignites it.
Heat comes off the insert as radiant heat and through a convection chamber that draws in room air, warms it around the firebox and sends it back out the front. Exhaust leaves through the flue collar (6″ on Lopi’s Answer and Flush models) into the chimney.
Insert vs. open fireplace
| Open wood fireplace | EPA-certified wood insert | |
|---|---|---|
| Where the heat goes | Most traditional open fireplaces lose over 90% of the fire’s heat up the chimney | Works like a wood stove; Lopi’s NexGen-Fyre inserts are rated 72% to 77.1% efficient (HHV) |
| Room air | Can send up to 300 cubic feet per minute of heated room air up the chimney | Door stays closed; an air control meters combustion air |
| Smoke | Not EPA-certified | No more than 2.0 g/h (2.5 g/h on the cordwood test) |
| Typical role | Ambiance and secondary heat | Primary or supplemental heat |
What EPA 2020 certification means
Each model is tested by an accredited lab. Since EPA’s Step 2 limit took effect on May 15, 2020, a new insert may emit no more than 2.0 grams of smoke per hour, or 2.5 g/h if tested with cordwood. The earlier limit was 4.5 g/h; older uncertified stoves release 15 to 30 g/h. EPA says a certified stove can use up to one-third less firewood than an older one.
- How to check: look for the permanent EPA label, typically on the back, or search EPA’s list of certified wood heaters.
- Certified is not “qualified”: EPA-qualified fireplace retrofit devices cut fireplace smoke about 70% but still emit more than a certified stove.
Catalytic, non-catalytic or hybrid?
| Non-catalytic | Catalytic | Hybrid | |
|---|---|---|---|
| Burns smoke at | About 1,100 F | About 500 F | Both systems |
| Average efficiency (EPA) | 71% (60-80%) | 78% (63-84%) | n/a |
| Strengths | Simpler to run, more visible flames; about 80% of the market | Long, even heat; cleanest at low burn rates | Lower emissions at low and high burns |
| Upkeep | Baffle and some internal parts wear out | Catalyst can last more than six seasons, or as little as 2 years if over-fired or fed trash | Combustor care plus baffle checks |
Lopi’s NexGen-Fyre inserts are non-catalytic; its NexGen-Hybrid versions add a combustor above the baffle. The Answer NexGen-Hybrid is listed at 1.4 g/h (crib-wood test) with burns up to 10 hours, versus 2.0 g/h (cordwood test) and 8 hours for the Answer NexGen-Fyre. Catalytic models have a bypass you open for start-up and reloading; Lopi’s Evergreen and Flush NexGen-Fyre inserts also have a bypass damper.
Sizing: fit the firebox, then the house
Every insert lists minimum fireplace dimensions. Lopi’s Answer NexGen-Fyre needs a masonry opening at least 23-5/8″ wide front and rear, 20-3/4″ tall and 14-1/2″ deep, a hearth at least 18″ deep, and a combustible mantel no lower than 35-1/2″ above the insert’s base. A zero-clearance (metal) fireplace needs 25-5/8″ of width and 15-1/2″ of depth, and there the combustible mantel must be at least 44″ above the insert’s base. Lopi’s optional GreenStart igniter (Flush models only) needs a wider opening, so confirm the fit for your configuration.
Then size the heat. The Department of Energy warns that an oversized unit gets run at a smolder, which wastes fuel and pollutes, while an undersized one won’t keep up. Its rule of thumb: about 60,000 Btu for 2,000 sq. ft.
| Lopi model | Firebox | Max log | Heating capacity | Max burn | Emissions |
|---|---|---|---|---|---|
| Answer NexGen-Fyre | 1.5 cu. ft. | 18″ | Up to 1,200 sq. ft. | 8 hr | 2.0 g/h |
| Evergreen NexGen-Fyre | 2.2 cu. ft. | 20-1/2″ | Up to 2,000 sq. ft. | 10 hr | 1.5 g/h |
| Medium Flush NexGen-Fyre | 2.2 cu. ft. | 24″ | 1,200-2,000 sq. ft. | 10 hr | 2.4 g/h |
| Large Flush NexGen-Fyre | 3.0 cu. ft. | 24″ | 1,500-2,500 sq. ft. | 12 hr | 1.7 g/h |
Specs are Lopi’s for the NexGen-Fyre versions; emissions are cordwood-test figures (limit 2.5 g/h). Lopi now lists the Evergreen and Flush models as NexGen-Hybrid, with different specs. Compare all of the Lopi wood fireplace inserts we carry.
Why most inserts need a chimney liner
In most regions the most common clay flue liner (nominal 8″ x 12″) has more than twice the area of a 6″ flue, and the Department of Energy warns that a flue bigger than the appliance outlet slows the exhaust and increases creosote buildup. What’s required depends on the insert’s listing:
- Lopi Answer NexGen-Fyre, masonry fireplace: a direct connection into a clay-tile liner with a sealed block-off plate, or a full-height stainless liner, which Lopi says gives the best draft and easiest cleaning.
- Lopi Answer NexGen-Hybrid: a full-height stainless liner, sealed with fireplace cement because the catalyst adds resistance.
- Lopi inserts in zero-clearance fireplaces: a 6″ stainless liner the full chimney height, rated UL 1777 type HT (2100 F).
Lopi also requires a chimney 15′ to 33′ tall and never allows an insert to share a flue with another appliance.
Blower and power needs
A wood insert heats without electricity: Lopi says its inserts don’t need the blower to operate and warm the home by natural convection during an outage. The blower pushes more heat into the room. It’s an optional 130 CFM fan on the Answer and Evergreen and a standard 180 CFM fan on the Medium Flush, and it switches on once the insert is hot, typically 15 to 30 minutes after lighting. Lopi notes efficiency may be lower with the blower off, so plan for power at the fireplace (Lopi offers a high-temperature insert wiring kit).
What installation looks like
- Measure and choose a model whose minimum opening, hearth and mantel dimensions you meet.
- Chimney inspection. Under NFPA 211’s inspection levels, CSIA recommends a Level 2 inspection, with a video scan of the flue, when adding an appliance or relining. Lopi requires a clean, undamaged fireplace and chimney, with repairs made first.
- Permits and insurance. Lopi says to check with local building officials about permits and inspections and to notify your insurer. Rules vary by town.
- Prep and liner. The damper is removed or locked open, and the liner is run, capped and sealed to the insert.
- Set and finish. The insert is leveled, surround panels go on and a “fireplace has been altered” plate is attached. In a masonry fireplace, Lopi’s Answer needs a noncombustible hearth extending 16″ in front and 6″ to each side (U.S.); in a zero-clearance fireplace the side extension is 8″.
- First fires cure the paint; Lopi says to ventilate and leave the room while the fumes clear.
Steps 2, 4 and 5 are for a qualified installer, not a DIY job: Lopi marks insert installation “for qualified installers only,” EPA strongly recommends professional installation, and DOE recommends having a professional examine the fireplace and chimney first.
Maintenance and creosote
Creosote is a highly combustible residue that forms when smoke condenses in the chimney; enough of it can start a chimney fire. EPA lists wet wood, restricted air, a cold chimney and an overloaded firebox as causes, and Lopi adds burning continually at a low setting.
- Burn wood under 20% moisture. EPA says to season softwood six months and hardwood at least a year; check with a moisture meter.
- Lopi says to inspect the chimney connector and chimney at least twice monthly during use and clean as needed.
- Have a professional inspect and clean the chimney and insert yearly (EPA); pulling an insert to clean is a sweep’s job (DOE).
- Keep the door closed except when loading; never use gasoline or other flammable liquids.
- Store ashes in a lidded metal container, outdoors on a noncombustible surface.
- Yearly, vacuum the blower and check firebrick and baffle; catalytic models also need combustor inspection.
- Install smoke and CO alarms on every floor and outside each bedroom (EPA).
When to call a qualified technician
- You smell smoke in the house, or smoke leaks into the room.
- The insert or connector glows red (over-firing): turn the air control to low and let it cool.
- The glass is cracked; don’t run the insert until it’s replaced.
- After a chimney fire or storm damage.
- Any repair your manual doesn’t cover.
When a wood insert is not the right fit
- The fireplace or chimney is damaged and won’t be repaired first.
- Your factory-built fireplace isn’t listed for the insert; EPA says it needs one designed and tested for that unit.
- The chimney is outside the manual’s height range, or the flue serves another appliance.
- The firebox, hearth or mantel can’t meet the minimums.
- You don’t want to handle firewood. EPA points to gas and pellet inserts as cleaner-burning options.
- Local rules limit it. DOE notes some municipalities restrict wood burning on poor air-quality days.
Decision checklist
- You want real heat, not just ambiance.
- Your fireplace is wood-burning masonry, or a factory-built model the insert’s manual lists.
- The opening, hearth and mantel meet the insert’s minimums.
- A Level 2 chimney inspection is done and any repairs are made before the insert goes in.
- The insert’s output matches the area you want to heat.
- You can season wood to under 20% moisture.
- You’ve checked permit rules with your village or city.
FAQ
How does a wood burning insert work?
It’s a wood stove built to fit inside your fireplace. Wood burns in a closed firebox with metered air, a second burn consumes most of the smoke, and a convection chamber, often with a blower, moves heat into the room instead of up the chimney.
Do I need a chimney liner for a wood insert?
Usually, and always if the manual says so. Some listings, such as Lopi’s Answer NexGen-Fyre in a masonry fireplace, allow a sealed direct connection into a clay-tile flue, but others, including Lopi’s zero-clearance installations, require a full-height stainless liner.
Can I put a wood insert in a prefab fireplace?
Only if the insert was designed and tested for that fireplace, EPA says. Lopi’s Answer NexGen-Fyre lists approved brands such as Majestic, Heatilator and Superior, while the Answer NexGen-Hybrid may not go in a factory-built fireplace at all.
Does a wood insert work during a power outage?
Yes. Lopi says its inserts heat by natural convection without the blower, though efficiency may be lower with the blower off.
How often should a wood insert and its chimney be inspected and cleaned?
EPA recommends a professional inspection and cleaning every year. Between visits, Lopi says to check the connector and chimney at least twice a month while the insert is in use.
Not sure which insert your fireplace can take? Bring your measurements and a photo to our Downers Grove showroom at 1202-B 75th Street, or call (630) 241-1919.