Gas Fireplace Inserts: How They Work, Fit and Size
Quick answer
A gas fireplace insert is a sealed, glass-front gas heater built to slide into an existing wood-burning fireplace: a masonry fireplace, or a listed factory-built (metal) one that the insert’s manual accepts. It burns natural gas or propane and vents through new liners run up the old chimney, usually one for outdoor air and one for exhaust. Choosing one comes down to whether your firebox meets the insert’s minimum opening, how much heat the space needs, and how you want it to behave in a power outage. The gas line, liners and hookup are work for a qualified technician.
How a gas fireplace insert works
Natural Resources Canada (NRCan) describes an insert as a gas burner and simulated logs in a metal housing that fits the existing fireplace cavity, with a glass front and decorative trim. Every model in this guide is direct vent: sealed from the room, each draws outdoor combustion air through one pipe and sends exhaust out another. In a relined chimney those pipes usually run as two separate liners, which NRCan calls collinear venting. A Building America information sheet published by the Department of Energy recommends sealed-combustion appliances because they are cut off from indoor air, which eliminates backdrafting concerns.
Heat comes through the glass as radiant heat, and room air circulating around the firebox comes back out warmer, which a fan can boost. For other venting types, see direct vent vs. ventless gas fireplaces.
Which fireplaces can take a gas insert
- Masonry fireplaces. Lopi and Fireplace Xtrordinair (FPX) manuals call for a code-conforming masonry fireplace; Majestic adds that the chimney must be noncombustible, clean and in good working order.
- Factory-built (metal) fireplaces. Only a tested and listed factory-built wood-burning fireplace; Majestic specifies one listed to UL 127. The damper and grate come out, but the insulation and structural frame stay, and cutting the fireplace’s sheet metal is prohibited except where the manual allows. FPX requires the fireplace to be permanently marked as altered and no longer suitable for wood unless the removed parts are reinstalled.
- Repairs first. Lopi and FPX both say to repair any fireplace damage before installation, and Lopi never allows the vent to share a chimney with another appliance.
Measuring your firebox
Each manufacturer lists a minimum opening, so measure the height at the front, the width at the front and at the back, and the depth. Majestic says to add 4″ to its minimum height if the insert’s exhaust collar and your damper don’t line up, for bends in the vent pipe. Usable depth depends on the trim: FPX’s 430 needs 15-1/2″ with its one-piece panel but 14-1/4″ with the panel trim kit. Lopi publishes a fireplace insert installation worksheet for recording these numbers.
Gas insert sizing: heat output, not just Btu input
Input is the fuel an insert can burn in an hour; output is the heat it delivers, which also depends on efficiency. NRCan says to size by output and calls oversizing a common problem: in a small room a high-output unit overheats the space and burns more gas than needed. Its fix is a lower-output model or one with wide turndown, the ability to dial the flame down; some units turn down only to 70% of full input, others to 20%. Lopi and FPX add that heating capacity varies with floor plan, insulation and outdoor temperature. For efficiency ratings and savings, see how fireplace inserts can save you money.
| Insert (natural gas) | Input, Btu/h | Heating area (maker) | Minimum opening, H x front W x D | Ignition |
|---|---|---|---|---|
| Lopi Radiant Plus Medium (MV or GSB) | Up to 25,000 | Up to 1,250 sq. ft. | 19-3/4″ x 27″ (17-1/4″ at back) x 15″ | Standing pilot (MV) or electronic with battery backup (GSB) |
| Lopi Radiant Plus Large (MV or GSB) | 17,000-33,000 | Up to 1,650 sq. ft. | 23-3/4″ x 31″ (21-1/4″ at back) x 15″ | Same choice as the Medium |
| FPX 430 Deluxe Ember-Glo | 9,900-31,000 | Up to 1,500 sq. ft. | 20-1/4″ x 30-1/2″ x 15-1/2″ | GreenSmart, continuous or intermittent pilot, battery backup |
| FPX 616 Deluxe Ember-Glo | 12,000-39,000 | Up to 2,000 sq. ft. | 24″ x 35″ x 16-1/2″ | Same as the 430 |
| Majestic Ruby 25 / 30 / 35 | 18,900-27,000 / 22,890-32,700 / 24,500-35,000 | Not listed | 17-5/16″ x 26-5/8″ / 21″ x 31-5/8″ / 24-1/4″ x 36-5/8″, all 15″ deep | IntelliFire Touch electronic ignition, battery backup |
Specs are from each maker’s literature; FPX openings assume its one-piece panel and Majestic’s its standard surround. Compare all the gas fireplace inserts we carry.
Surround panels and fit
The surround hides the gap between the insert and your existing opening, so it has to be bigger than the opening. Majestic offers Ruby 25 surrounds from 35″ x 23″ to 39″ x 28″, plus custom ones; its standard surrounds are under an inch deep (the installation manual gives both 3/4″ and 7/8″), and a deeper one reduces usable firebox depth. Lopi offers small and large panels, custom three- and four-sided panels, and a Universal face that may not need a panel.
Check the mantel too, measured from the insert’s base: Lopi’s Radiant Plus Medium needs a combustible mantel 5″ to 12″ deep at least 34″ up (33″ if 4″ deep or less), and the Large needs 36-1/2″. FPX says surrounds must not seal the fireplace’s ventilation openings, and NRCan says to check the manual before adding or changing a mantel or surround.
Standing pilot vs. electronic ignition
| Standing pilot (millivolt, MV) | Electronic intermittent pilot (IPI) | |
|---|---|---|
| Pilot | Burns continuously; NRCan says a pilot alone can use 600 to 1,500 Btu of gas per hour | Lights only when heat is called for (Lopi GSB) |
| House power | Not needed to run the fire (Lopi Radiant Plus MV) | Runs on house power, with batteries as backup |
| Power outage | The fire keeps working; Lopi’s optional fan still needs 120 V | Battery backup on Lopi GSB and FPX GreenSmart; Majestic’s 4 AA pack runs the Ruby up to 72 hours |
| Good fit if | You want heat that doesn’t depend on electricity | You want to stop paying for a pilot that burns all season |
FPX’s GreenSmart lets you choose continuous or intermittent pilot. With a standing pilot, NRCan suggests one that is easy to shut off and relight so it can be off in summer; see how to light a gas fireplace.
Blower, remote and thermostat
A fan pushes convective heat into the room; NRCan suggests a quiet, variable-speed one. Fans need house power: Lopi’s optional 100 CFM fan requires 120 V, FPX’s 430 includes a 180 CFM fan, and Majestic’s Ruby manual calls for unswitched 110-120 V power at the insert, which its IntelliFire Touch ignition also needs. Plan the outlet before installation.
Lopi’s optional remote has manual on/off and thermostat modes. FPX’s GreenSmart remote, included with the 430 and 616, adds a childproof feature, and Majestic’s Ruby runs on IntelliFire Touch, controlled by a touchscreen remote or wireless wall switch, with an optional Wi-Fi module and app. NRCan says a thermostat works best with wide turndown, adjusting the flame instead of cycling on and off. Because a thermostat can light the fire on its own, FPX warns against leaving anything on or near the insert.
What installation involves
- Measure and inspect. Confirm the opening, mantel and chimney meet the manual; the fireplace, smoke shelf and chimney are cleaned and any damage repaired (Lopi, FPX).
- Permit and insurance. FPX says to ask local building officials about a permit and inspection and to notify your insurer. Rules vary by town.
- Gas and power. The gas line is run to the fireplace first. NFPA 54, the National Fuel Gas Code, limits installing, testing and purging gas piping and appliances to a qualified agency, and new piping is leak-checked when gas is turned on.
- Damper and liners. The damper is removed or blocked open (Majestic). Lopi’s Radiant Plus uses two 3″ gas liners, exhaust and intake; the exhaust must reline the full chimney and end above its top, within a 16′ to 40′ vent height on the Medium GSB.
- Set and finish. The installer levels and connects the insert, fits the face and surround, installs the safety barrier and fixes the “This fireplace has been altered” plate to the old fireplace.
- Start-up. Gas joints are leak-tested, and Lopi has the installer burn the insert 15 minutes and adjust the air shutter for yellow flames with no soot.
Steps 3 to 6 are for a qualified technician: Lopi marks installation “for qualified installers only,” and FPX calls for an installer trained on direct vent gas appliances.
Living with it safely
Hot glass is the everyday hazard. A 2012 statement by the CPSC chairman put gas fireplace glass at 500 to 1,000 degrees; new inserts such as FPX’s ship with a barrier screen that must be installed, and the hearth industry group HPBA says cool-down can take an hour or more. CPSC also recommends CO alarms on every level and outside sleeping areas, and having the heating system professionally inspected every year, including chimneys and flues.
When a gas insert is not a fit
- Your firebox is smaller than the insert’s minimum opening.
- Your factory-built fireplace isn’t a listed wood-burning unit the insert’s manual accepts.
- The chimney is damaged or combustible and won’t be repaired, or the flue serves another appliance.
- The chimney height falls outside the vent limits in the manual.
- You still want to burn wood. A converted factory-built fireplace is marked as no longer suitable for wood; our wood burning fireplace insert guide covers that route.
Decision checklist
- Your fireplace is masonry, or a listed factory-built wood-burning unit the manual allows.
- Your front and back width, height and depth meet the model’s minimums.
- Heat output and turndown suit the room, not just maximum input.
- You’ve chosen standing pilot or electronic ignition with battery backup.
- The surround covers your opening, the mantel meets clearances and there’s power for a fan.
- A qualified technician will handle the gas line, liners and permit, and CO alarms are on every level.
FAQ
How does a gas fireplace insert work?
It’s a sealed gas heater that fits inside your existing fireplace. On a direct vent model, outdoor air comes down one liner and exhaust goes up another, while heat radiates through the glass and circulates around the firebox, often helped by a fan.
Can you put a gas insert in a wood-burning fireplace?
Yes. NRCan describes inserts as converting wood-burning masonry or factory-built metal fireplaces to gas. A factory-built unit must be listed and accepted by the insert’s manual, and the chimney must be relined with an approved vent.
What size gas fireplace insert do I need?
First it has to fit: compare your firebox’s front and back width, height and depth with the insert’s minimum opening. Then match heat output to the space; NRCan warns that oversizing is common, so good turndown helps.
Does a gas fireplace insert work during a power outage?
Many do. A standing-pilot insert such as Lopi’s Radiant Plus MV needs no power, and electronic-ignition models such as the Radiant Plus GSB and Majestic Ruby have battery backup. The fans on these models need house power.
Can I install a gas insert myself?
No. NFPA 54 limits gas piping and appliance installation to a qualified agency, Lopi, FPX and Majestic all call for qualified installers, and your village or city may require a permit and inspection.
Not sure which insert your fireplace can take? Bring your firebox measurements and a photo to our Downers Grove showroom at 1202-B 75th Street, or call (630) 241-1919.